- Product name:Fuel cell tester - Vertical 664W
- Category:SLT Testing Equipment
- Back to list
Production Instruction:
For this fuel cell tester’s design, we consider the stability, save the space and make high performance cost ratio. It is suitable for the single cell of PEMFC; It can humidify fuel -and air-grade gases. Control and measure software sets friendly graphical user interface, it is easy to control the parameters of the fuel cell test system.
Functional features:
*Fully integrated and compact structure
* Suitable for single battery (PEMFC)
* Accurate gas flow control
* Accurate temperature and humidity control
* Precise dedicated electronic load for fuel cell
*Multiple safety function
*Complete software functions
Parts System | Parameter | Remark |
Liquid Fuel Control System | ||
Hydrogen Flow Range | 0-2000SCCM | Software or Key setting |
Flow Control Accuracy | ±3% of FS | |
Negative Pole Gas Supply System | ||
Air Flow Range | 0-5000SCCM | Software or Key setting |
Air Flow Test Accuracy | ±0.3%FS | |
Purification | ||
Positive and negative are set three - way valves, Nitrogen purge automatically | Software Setting | |
Humidifying | ||
Humidifying to keep the Temperature Range | +10℃~99℃ | |
Humidifying Accuracy | ±0.5℃ | |
Humidifying to keep warm for the discharged gas | Silicone rubber heat ribbon, Keep warm with thermal cotton | Smart PID,Software or Key setting |
Fuel Cell Thermal Management System | ||
Model | Positive and negative extreme plate heating control, Panel heating port output | Equipped with 4 pieces of 50W ceramic heating rods |
Extreme Plate Heating Power | 220V AC/200W | |
Temperature Control Range | Normal~99℃ | |
Temperature Control Accuracy | ±1℃ | Smart PID,Software or Key setting |
Cell Temperature Test Range | 0~300℃ | |
Electronic Load | ||
Rated Power | GG 4W(Multiple specification) | |
Current Range | 0~132A | Three Groups: Resolution:0.01mA, 0-1.5A, Resolution:0.1mA, 0-15A, Resolution:1mA, 0-15A, |
Voltage Range | 0~150V (OV discharge) | OV action, Special discharge of fuel cells in an OV state |
Measure Accuracy | ±0.2%FS; ±0.2% SET POINT | |
Current Corresponding Time | Rise time<10us | High velocity response, Suitable For Fuel Cell Transient Analysis |
Work Model | Constant current/voltage/ resistance discharge | Remote working mode |
Safety Protection System | ||
Security Alarm | Safe upper limit for over-temperature and input voltage, Lower limit of protection for cell voltage | Brake application, Automatic load breaking, stop heating power |
Protection Method | Loop insurance, System emergency braking | |
Software Controls and Data Acquisition System | ||
Test Software For Fuel Cell Control System | PEMFCTEST1.0 | Function of any - time high - speed, can generate associated graphs and data acquisition system as needed, TXT or Excel to save(Temperature, Flow, Voltage, Current, Test Time, Etc) |
Test equipment working environment requirements | ||
Power Supplier | 220V, Max Current 10A. power fluctuation is +/-10% | |
Gas supplier | 0.05-2.5Mpa | |
Environment Temperature | -20-45℃ | |
Environment Humidity | <95%RH | |
Product Appearance | ||
Volume | 350mm*550mm*600mm | |
Weight | 75KG | |
Remark: The Appearance will be a little different according to customer’s Configuration requirements; the specific appearance shall be subject to the actual object. |