- Product name:SP202 Bi-component Spraying Device
- Category:SLT Spraying Equipment
- Back to list
SP202 Bi-component Spraying Device
It uses dual-line feeder and sprays at the spray head on blended reaction. It can be used in spraying two different slurries at the same time, which can effectively prevent the subsidence, denaturation and solidification caused by slurry mixing earlier.
This device uses electrostatic spraying theory, and can achieve slurry utilization up to 97.5%. High slurry spraying uniformity can assure its stability and repeatability on sample preparation.
Features:
1. Be suitable for spraying two slurries of different ingredients, and mixing what you spray, which decrease the waste of mixed slurries and decrease the waste caused by mixed surplus of man-made.
2. Uses precision injection pump, which can effectively assure its clearness of distribution from two sets.
3. Desk-type design with reasonable and compact structure, and the size of overall device is just a common printer, thus it can be placed conveniently on the draught cupboard, laboratory table etc. It is very suitable for Universities and research institute etc.
4. Can make a case customization for every clients.
Technical Data:
Environmental Condition d | Items | Parameters |
Cylinder Working Pressure | 0.50-0.80 MPa | |
Environment Temperature | 0-55℃ | |
Environment Humidity | 10-85% | |
Anti-vibration | 10-25Hz(X,Y,Z direction 30min respectively) output material | |
Anti-interference | 1000Vp-p | |
Surrounding Air | No Corrosive Gas | |
Electric Specs
| Power Supply Voltage& frequency | Single Phase AV 220V 50Hz |
Maximum Consumption Power | ≤4kw | |
Ground Resistance | <100Ω | |
Working Control Voltage | DC/24V | |
Structure Parameters | Spaying Active Area | 400*400mm |
Cast Alu Heating Specs | 400*400*25mm | |
Size | 1100*1000*1600mm | |
Weight | 300kgs | |
Spaying Parameters | Maximum Spraying Speed | 0-30000mm/min |
Maximum Spraying Qty | 25ml-500ml/times | |
Repeat Position Accuracy | 0.01mm | |
Flow Setting Range | 0.01ml/min—30ml/min | |
Flow Setting Accuracy | ≤±1.50% | |
Flow Repeat Accuracy | ≤±1.50% | |
Gas Working Pressure | ≤±1.50% | |
Medium Status | Weak corrosion | |
Medium Viscosity | ≤50㎜²/S | |
Heating Temperature | 25℃--120℃ | |
Heating Accuracy | ±1% |